• TJ-12

AM1 Regulating Main valve DN20-100

Short Description:


Product Detail

Product Tags

Technical parameters

  • Nominal pressure: 2.8MPa
  • Applicable temperature:-50℃ ~+120°c
  • Test pressure:4.2MPa
  • Applicable medium: ammonia, fluorine, propane,etc.

Characteristics

  • Flow regulating valves, servo-operated by different pilot valves screwed-in the main valve or mounted in an external pilot line.
  • The AM1 are designed to use with ammonia and other common fluorinated refrigerants,for liquid,suction,discharge or defrosting lines, and they have one port, thus, you can screw-in one pilot valve only.
  • The thread to screw-in the pilot valves is M24x1.5,and the pressure gauge connection 1/4″BSP.
  • The degree of opening of AM1 valves is function of the differential pressure between the inlet and outlet,so if the pressure difference is Ap = 0.3 bar, the main valve will be fully open, and if it is ap = 0.2~0.3 bar, the degree of opening will be correspondingly proportional to Ap.

AM1 main valve-2

Name Type Size(mm) Kv Cv
DN ΦD Φd A H L L1
AM1
Main Valves Type
AM1 20 3/4″ 20 27 20 65 150 190 125 6 7
AM1 25 1″ 25 34 25 65 150 190 125 9 10.5
AM1 32 1 1/4″ 32 42 32 70 175 245 170 16 19
AM1 40 1 1/2″ 40 48 40 70 175 245 170 30 35
AM1 50 2 50 60 50 70 180 255 180 40 47
AM1 65 2 1/2″ 65 76 65 85 205 295 220 75 88
AM1 80 3″ 80 89 80 95 225 330 250 140 164
AM1 100 4″ 100 108 100 125 260 415 330 200 234

  • Previous: