ACVPP pressure conrol pilot valve
Technical parameters
- Nominal pressure: 2.8MPa
- Applicable temperature:-50℃ ~+120°c
- Test pressure:4.2MPa
- Applicable medium: ammonia, fluorine, propane,etc.
Characteristics
- The Pilots ACVPP are used as differential pressure regulators,mounted directly over main valves AM1 or AM3 but can be also mounted on a housing valve ACVH in a external line to control one or more AM or RAK valves.
- The Pilots ACVPP working by differential pressure with a, range of regulation of 0 Bars to 10 Bars.
- Turning the regulating spindle clockwise, increases the opening differential pressure of the pilot, ( thus the evaporating pressure for ex.) and it decreases when we turn the spindle anticlockwise.
- This guide valve is used to keep the difference between AM inlet pressure and ACVPP reference pressure constant.
Pilot type | Maximum working pressure(bar ) |
KV(m3/h) | Temperrature range (℃) |
Pressure range (bar ) |
ACVPP | 28 | 0.4 | -50/+120 | 0-10 |
Pilot seat | L | L1 | H | D | d1 | B |
ACVH | 70 | 50 | 35 | 23.5 | NPT3/8 | M24x1.5 |